CHEMICAL ANALYSIS

This examination is commonly used to determine the material and filler metal that has been used for construction.
In accordance with the necessity to measure C, P, and S, is defined the instrument to be udsed.

P.M.I.

Positive Material Identification, is carried out in inert gas atmosphere (Argon).
This allow to measure all elements to discriminate the material and not only the alloy.

P.A.M.I.

Positive Material Alloy Identification, , is carried out in air using a X-Ray detector.
This allow to measure all elements to discriminate the alloy.
Both equipment record all the data to allow a correct trace ability of the analysis.




  P.A.M.I.

  P.M.I.




FERRITE TEST

This examination is carried out in order to define the ferrite contents for cladded  weld deposit and for all stainless steel welding, to verify the correctness of the filler metal used.



Ferrite test